Q65550: SHELL "CHDIR", "Input Path for Run-Time Module" if No BC /O
Article: Q65550
Product(s): See article
Version(s): 7.00 7.10
Operating System(s): MS-DOS
Keyword(s): ENDUSER | SR# S900823-137 buglist7.00 buglist7.10 B_QuickBas | mspl13_basic
Last Modified: 14-DEC-1990
A SHELL statement that changes the current directory or drive (using
DOS's CHDIR command) will display the following message when returning
control to the BASIC program if the program is compiled to require the
BASIC run-time module (compiled without BC /O):
Input path for run-time module brt7nxxx.EXE [or brun4n.EXE,
or brun6nxx.EXE]
This problem occurs only when you run the .EXE from its own directory,
and BASIC's run-time module is also in that current directory. The
problem does not occur if the .EXE or the run-time module is in a
non-current directory (that is along the DOS PATH).
Microsoft has confirmed this to be a problem in the Microsoft BASIC
Professional Development System (PDS) versions 7.00 and 7.10 for
MS-DOS; in Microsoft QuickBASIC versions 4.00, 4.00b, and 4.50
(buglist4.00, buglist4.00b, buglist4.50) for MS-DOS; and in Microsoft
BASIC Compiler versions 6.00 and 6.00b (buglist6.00, buglist6.00b) for
MS-DOS. We are researching this problem and will post new information
here as it becomes available.
This problem does not occur in an OS/2 protected-mode program (in
BASIC 6.00, 6.00b, 7.00, or 7.10).
Any one of the following works around the problem:
1. Create a stand-alone (BC /O) .EXE file.
2. Run your compiled .EXE while a different directory is the current
directory. For example, if your PROG.EXE program is in the
directory C:\DIR1, then log on to any other directory and run
C:\DIR1\PROG or take advantage of the DOS PATH to find PROG.EXE.
(This problem occurs only when the current directory is the same
directory as where both the PROG.EXE program and the BASIC run-time
module sit.)
Code Example
------------
The code example below duplicates the problem. Compile as follows:
BC TEST.BAS;
LINK TEST;
To duplicate the problem, put both the TEST.EXE program and the BASIC
run-time module (BRT7nxxx.EXE or BRUN4n.EXE or BRUN6nxx.EXE) into a
subdirectory, make that subdirectory the current directory, then run
TEST.EXE.
' TEST.BAS
SHELL "CHDIR \"
PRINT "TEST"
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.