Q64163: /Zp Default Values with and without Specifying the Switch

Article: Q64163
Product(s): See article
Version(s): 5.10 6.00 | 5.10 6.00
Operating System(s): MS-DOS | OS/2
Keyword(s): ENDUSER | | mspl13_c
Last Modified: 31-AUG-1990

When specifying the /Zp switch with either version 5.10 or 6.00 of the
Microsoft C Optimizing Compiler, it should be observed that the
default functionality when using the /Zp switch without a numeric
argument is equivalent to /Zp1 (that is, structure members will be
packed on one-byte boundaries).

Additionally, if the /Zp switch is not specified, the structure
members will be packed on two-byte boundaries (that is, the equivalent
of using /Zp2).

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.