Q62170: PRB: Modifying TOOLS.INI May Have No Effect on PWB Environment

Article: Q62170
Product(s): Microsoft Programming Utilities
Version(s): MS-DOS:1.0,1.1; OS/2:1.0,1.1
Operating System(s): 
Keyword(s): kb16bitonly
Last Modified: 31-OCT-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Programmer's Workbench for MS-DOS, versions 1.0, 1.1 
- Microsoft Programmer's Workbench for OS/2, versions 1.0, 1.1 
-------------------------------------------------------------------------------

SYMPTOMS
========

Changing settings in the TOOLS.INI file to modify the behavior of the
Programmer's WorkBench (PWB) may not work under certain circumstances. For
example, if you decide to change the PWB to 50-line mode by setting "height:50"
in the TOOLS.INI file, it will not work if the PWB was previously used in the
25- or 43-line mode.

CAUSE
=====

This is because some environment information is also recorded in the CURRENT.STS
file, which is read in after the TOOLS.INI file -- overriding the TOOLS.INI
settings.

RESOLUTION
==========

The following are three workarounds for this problem:

1. Use the /DS switch when invoking the PWB. This will ignore the CURRENT.STS
  file. However, this option also causes the current file history (of files
  being edited) to be ignored.

2. Delete the CURRENT.STS file. This also causes the current list of programs
  being edited to be ignored.

3. The better option is to select Editor Settings from the Options menu. When
  the list of editor switch settings appears, it can be changed and saved to
  the TOOLS.INI file by pressing SHIFT+F2. This will save the settings and
  cause the selection to take effect.

Additional query words: 1.00 1.10 PWBIss

======================================================================
Keywords          : kb16bitonly 
Technology        : kbAudDeveloper kbPWBSearch kbZNotKeyword3 kbPWB100DOS kbPWB110DOS kbPWB100OS2 kbPWB110OS2
Version           : MS-DOS:1.0,1.1; OS/2:1.0,1.1

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.