Q47456: MASM Err Msg: Error L2002: Fixup Overflow
Article: Q47456
Product(s): See article
Version(s): 5.10
Operating System(s): MS-DOS
Keyword(s): ENDUSER | | mspl13_masm
Last Modified: 12-SEP-1989
The following message occurs when data defined in the data segment is
overridden with a Segment Override using the code segment register:
foo.OBJ(foo.ASM): error L2002: fixup overflow at 0012 in segment_TEXT
pos: 658 Record type: 73EE
frm seg _TEXT, tgt seg _DATA
This error occurs when you incorrectly try to access data in the code
segment rather than in the data segment in the following line:
mov word ptr cs:old_dma_vect,bx ;
The line should be as follows:
mov word ptr ds:old_dma_vect,bx ;
Code Sample:
.DATA
old_dma_vect dd 0
.CODE
;
capture proc
.
.
.
mov word ptr cs:old_dma_vect,bx ; (INCORRECT)
mov word ptr ds:old_dma_vect,bx ; (CORRECT)
.
end capture
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.