An error will occur if the LIB environment variable is improperly set
using a forward slash (/) instead of a backslash (\) in the SET line
in DOS.
The following line is incorrect:
SET LIB=C:/LIB
The following line is correct:
SET LIB=C:\LIB
QuickBASIC Version 3.00 generates the LINK "unrecognized switch"
error message when this problem occurs.
QuickBASIC Versions 4.00, 4.00b, and 4.50, the BASIC compiler Versions
6.00 and 6.00b for MS-DOS and OS/2, and Microsoft BASIC PDS Version
7.00 for MS-DOS and MS OS/2 generate the LINK error message L1002
"Unrecognized option name" when this problem occurs.
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.