Q171794: Migrate On/Off Does Not Allow Overwriting Static <1Ch> Mappings

Article: Q171794
Product(s): Microsoft Windows NT
Version(s): winnt:3.51,4.0
Operating System(s): 
Keyword(s): kbnetwork
Last Modified: 09-AUG-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows NT Server versions 3.51, 4.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

The static <1Ch> entries in your Windows Internet Name Service (WINS)
servers are not being overwritten by dynamic entries, even though you have
Migrate on/off enabled.

RESOLUTION
==========

To resolve this problem, manually delete the static mappings using one of the
following methods:

- Delete the static mapping entries by using WINS Manager:

  1. From the Mappings menu, click Static Mappings.

  2. Click the appropriate mapping, and then click Delete Mapping.

  3. Click Yes to confirm the deletion.

- Use the Winscl tool that is included in the Microsoft Windows NT 4.0 Resource
  Kit. Refer to the online help for Winscl, by typing "winscl.exe /?" (without
  the quotation marks) at a command prompt.

After you remove the static entries, you need to restart the domain controllers
for the domain or the entries are not refreshed until half of the domain
controllers' renewal interval with WINS.

NOTE: This is especially important in the case of <1Ch> entries, because
these entries are queried by clients requesting domain controllers for domain
logon validation. If clients are unable to obtain a list of domain controllers
from WINS they may receive a "domain controller not found" error message, and in
many cases, they may lose access to domain resources.

STATUS
======

This problem was first corrected in Microsoft Windows NT 4.0 Service Pack 4.

REFERENCES
==========

For additional information, click the article number below to view the article
in the Microsoft Knowledge Base:

  Q199159 Replacing a WINS Static 1c with a Dynamic Entry with Windows NT 4.0
  SP4

Additional query words:

======================================================================
Keywords          : kbnetwork 
Technology        : kbWinNTsearch kbWinNT351search kbWinNT400search kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbWinNTS351 kbWinNTS351search
Version           : winnt:3.51,4.0
Issue type        : kbprb

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.